<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="/sponet/themes/root/assets/xsl/rss.xsl"?>
<rss version="2.0" xmlns:opensearch="http://a9.com/-/spec/opensearch/1.1/" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:slash="http://purl.org/rss/1.0/modules/slash/">
  <channel>
    <title>Ergebnis für Versionen - 4004184</title>
    <description>Treffer 1 - 2 von 2</description>
    <generator>Laminas_Feed_Writer 2 (https://getlaminas.org)</generator>
    <link>https://sponet.de/sponet/Search/Versions?sort=first_indexed+desc%2Cfirst_indexed+desc&amp;limit=50&amp;id=4004184&amp;search=versions&amp;lng=de</link>
    <opensearch:totalResults>2</opensearch:totalResults>
    <opensearch:startIndex>0</opensearch:startIndex>
    <opensearch:itemsPerPage>50</opensearch:itemsPerPage>
    <opensearch:Query role="request" searchTerms="4004184" startIndex="0"/>
    <atom:link rel="first" type="application/rss+xml" title="Zur ersten Seite springen" href="https://sponet.de/sponet/Search/Versions?sort=first_indexed+desc%2Cfirst_indexed+desc&amp;limit=50&amp;view=rss&amp;id=4004184&amp;search=versions&amp;lng=de"/>
    <atom:link rel="last" type="application/rss+xml" title="Zur letzten Seite springen" href="https://sponet.de/sponet/Search/Versions?sort=first_indexed+desc%2Cfirst_indexed+desc&amp;limit=50&amp;view=rss&amp;id=4004184&amp;search=versions&amp;lng=de&amp;page=1"/>
    <atom:link rel="self" type="application/rss+xml" href="https://sponet.de/sponet/Search/Versions?sort=first_indexed+desc%2Cfirst_indexed+desc&amp;limit=50&amp;view=rss&amp;id=4004184&amp;search=versions&amp;lng=de"/>
    <item>
      <title>Die hämatologische Reaktion auf eine Eiseninjektion bei Sportlerinnen</title>
      <pubDate>Thu, 01 Jan 1998 06:01:27 +0100</pubDate>
      <link>https://sponet.de/sponet/Record/4004184</link>
      <guid>https://sponet.de/sponet/Record/4004184</guid>
      <author>Ashenden, M. J.</author>
      <author>Fricker, P. A.</author>
      <author>Ryan, R. K.</author>
      <author>Morrison, N. K.</author>
      <author>Dobson, G. P.</author>
      <author>Hahn, A. G.</author>
      <dc:format>Artikel</dc:format>
      <dc:subject>weiblich</dc:subject>
      <dc:subject>Therapie</dc:subject>
      <dc:subject>Basketball</dc:subject>
      <dc:subject>Mineral</dc:subject>
      <dc:subject>Mangel</dc:subject>
      <dc:subject>Blut</dc:subject>
      <dc:format>Artikel</dc:format>
      <dc:creator>Ashenden, M. J.</dc:creator>
      <dc:creator>Fricker, P. A.</dc:creator>
      <dc:creator>Ryan, R. K.</dc:creator>
      <dc:creator>Morrison, N. K.</dc:creator>
      <dc:creator>Dobson, G. P.</dc:creator>
      <dc:creator>Hahn, A. G.</dc:creator>
      <content:encoded><![CDATA[The aim of this study was to monitor the haematological response of female athletes with moderately low ferritin values to an iron injection. We measured the total haemoglobin mass of 11 female basketballers with a range of ferritin values who lived and trained together for the duration of the study (age 18+/-1, range 16-19 yrs), [Hb] 12.4+/-1.3, 11.5-16.1 g x dL; ferritin 35.6+/-15.6, 9-58 microg x L). A total dose of 2.5 mL Ferrum H was administered to six squad members who were matched with the remaining five controls based on ferritin measures obtained three weeks earlier. Venous blood samples were drawn weekly to obtain full blood counts, reticulocyte parameters as well as iron profiles. There was no change detected in any of the haematological parameters measured in the treatment group compared to controls. A repeated measures ANOVA (treatment x time) demonstrated that neither total haemoglobin mass (P = 0.91) nor [Hb] (P = 0.79) altered significantly between groups, whilst the mean haemoglobin content of reticulocytes also showed no response (P = 0.17). Because a positive haematological response is definitive evidence of impaired red cell production, our results indicate that none of the athletes were iron deficient at the time of the injection. This suggests that low ferritin values in trained female athletes are not always associated with impaired red cell production.]]></content:encoded>
      <slash:comments>0</slash:comments>
    </item>
    <item>
      <title>Die hämatologische Reaktion auf eine Eiseninjektion bei Sporlerinnen</title>
      <pubDate>Thu, 01 Jan 1998 06:01:27 +0100</pubDate>
      <link>https://sponet.de/sponet/Record/3028977</link>
      <guid>https://sponet.de/sponet/Record/3028977</guid>
      <author>Ashenden, M. J.</author>
      <author>Fricker, P. A.</author>
      <author>Ryan, R. K.</author>
      <author>Morrion, N. K.</author>
      <author>Dobson, G. P.</author>
      <author>Hahn, A. A. G.</author>
      <dc:format>Artikel</dc:format>
      <dc:subject>Biochemie</dc:subject>
      <dc:subject>weiblich</dc:subject>
      <dc:subject>Mineral</dc:subject>
      <dc:subject>Mangel</dc:subject>
      <dc:subject>Blut</dc:subject>
      <dc:subject>Farbe</dc:subject>
      <dc:subject>Basketball</dc:subject>
      <dc:subject>Körper</dc:subject>
      <dc:format>Artikel</dc:format>
      <dc:creator>Ashenden, M. J.</dc:creator>
      <dc:creator>Fricker, P. A.</dc:creator>
      <dc:creator>Ryan, R. K.</dc:creator>
      <dc:creator>Morrion, N. K.</dc:creator>
      <dc:creator>Dobson, G. P.</dc:creator>
      <dc:creator>Hahn, A. A. G.</dc:creator>
      <content:encoded><![CDATA[Ziel der Untersuchung war die Kontrolle der hämatologischen Reaktion von Sportlerinnen mit niedrigm Ferritinspiegel auf eine Eiseninjektion. Von 11 Basketballspielerinnen, die während der Untersuchung zusammenlebten und trainierten und verschiedenen Ferritinwerten aufwiesen, wurde die Gesamt-Hämoglobinmasse ermittelt. 6 Probanden wurde eine Eiseninjektion mit einer Gesamtdosis von 2.5 ml Ferrum H verabreicht, die übrigen Probanden dienten als Kontrollgruppe.
Ergebnis: In keinem der hämatologischen Parameter wurde im Vergleich zur Kontrollgruppe Veränderungen beobachtet. Weder die Gesamt-Hb-Masse noch Hb veränderten sich zwischen den Gruppen signifikant. Auch der mittlere Hämoglobinspiegel der Retikulozyten zeigte keine Reaktion. Da eine positive hämaotologische Reaktion der definitive Nachweis für eine beeinträchtigte Erythrozytenproduktion ist, weisen die Ergbenisse darauf hin, daß keine Sportlerin zur Zeit der Injektion Eisenmangel aufwies. Es wird geschlußfolgert, daß niedrige Ferritinspiegel bei Sportlerinnen nicht immer mit einer beeinträchtigten Erythrozytenproduktion verbunden sind.]]></content:encoded>
      <slash:comments>0</slash:comments>
    </item>
  </channel>
</rss>
